Healthcare Solutions

Who We Are

Healthcare Solutions is a team of former hospital administrators who help LAAC programs identify opportunities to accelerate their program success and development.

decorative orange rule

Our Approach

Through our Calibration Program and the steps below, we identify and tailor solutions to optimize your LAAC program. This process allows us to understand your program’s challenges and opportunities and develop a strategy that enhances your program’s performance.

orange number one in white circle

Discovery

We interview key program stakeholders to understand the current state of your program and vision for the future.

orange number two in white circle

Strategic Planning

We create an Action Plan with recommended solutions based on real-time feedback and data.

orange number three in white circle

Application

You decide which solutions to prioritize within your program and we provide ongoing support to help you succeed.

“Through the Calibration Program, one of my largest accounts has made extensive progress in almost every area of their program –from business development, to marketing, to operational efficiencies, to implant and referral success. They also saw their pipeline of patients grow by 5x in just a few months!”
— WATCHMAN Territory Manager

physicians and hospital administrators sitting together in discussion with decorative orange overlay

Benefits

The solutions included in our Action Plans focus on enhancing program quality, increasing referrer engagement, and improving procedural efficiencies.

physician hand holding WATCHMAN Device with patient smiling in background

Enhanced Program Quality

  • Reduce patient delays and wait times 
  • Improve patient awareness and access to therapy

physicians in hospital

Increased Referrer Engagement

  • Data driven insights to analyze and grow referrals
  • Education and activation to drive therapy awareness
  • Technology opportunities to identify and manage patients

physicians in scrubs

Improved Procedural Efficiencies

  • Program structure to bring together a comprehensive care team
  • Hospital and clinic care coordination
  • Cardiovascular Cath Lab operational improvement

The Proof

Our team has partnered with 500+ implanting centers across the U.S. and has a deep understanding of the challenges and opportunities within LAAC programs. These engagements have enabled some programs to achieve up to a 45% increase in implant volume in 12 months.

hallway of medical facility and waiting room chairs with decorative teal overlay

 

CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician. Rx only. Prior to use, please see the complete “Instructions for Use” for more information on Indications, Contraindications, Warnings, Precautions, Adverse Events, and Operator’s Instructions.

INTENDED USE/INDICATIONS FOR USE

The WATCHMAN FLX Device is indicated to reduce the risk of thromboembolism from the left atrial appendage in patients with non-valvular atrial fibrillation who:

  • Are at increased risk for stroke and systemic embolism based on CHADS2 or CHA2DS2-VASc scores and are recommended for anticoagulation therapy;
  • Are deemed by their physicians to be suitable for anticoagulation therapy; and
  • Have an appropriate rationale to seek a non-pharmacologic alternative to anticoagulation therapy, taking into account the safety and effectiveness of the device compared to anticoagulation therapy.

CONTRAINDICATIONS

Do not use the WATCHMAN FLX Device if:

  • Intracardiac thrombus is present.
  • An atrial septal defect repair or closure device or a patent foramen ovale repair or closure device is present.
  • The LAA anatomy will not accommodate a Closure Device (see Table 45 of the eIFU).
  • The patient has a known hypersensitivity to any portion of the device material or the individual components (see Device Description section of the eIFU) such that the use of the WATCHMAN FLX Device is contraindicated.
  • Any of the customary contraindications for other percutaneous catheterization procedure (e.g., patient size too small to accommodate TEE probe or required catheters) or conditions (e.g., active infection, bleeding disorder) are present.
  • There are contraindications to the use of anticoagulation therapy, aspirin, or P2Y12 inhibitor.

WARNINGS

Implantation of the WATCHMAN FLX Device should only be performed by interventional cardiologists and/ or electrophysiologists who are trained in percutaneous and transseptal procedures and who have completed the WATCHMAN FLX Physician Training program.

  • This device has not been studied in pregnant or breastfeeding women. Careful consideration should be given to use of the Closure Device in pregnant and/ or breastfeeding women due to the risk of significant exposure to x-rays and the use of anticoagulation medication.
  • Device selection should be based on accurate LAA measurements obtained using echocardiographic imaging guidance in multiple views (TEE recommended in multiple angles [e.g., 0°, 45°, 90°, 135°]) to avoid improper Closure Device sizing.
  • Do not release (i.e., unscrew) the WATCHMAN FLX Device from the core wire unless all release criteria are satisfied to avoid suboptimal results.
  • Potential for Closure Device embolization exists with cardioversion < 30 days following Closure Device implantation; verify Closure Device position after cardioversion during this period.
  • Appropriate post-procedure drug therapy should be followed. See Post-Procedure Information section (of the eIFU) for further detail.

PRECAUTIONS

  • The safety and effectiveness (and benefit-risk profile) of the WATCHMAN FLX Device has not been established in patients for whom long-term anticoagulation is determined to be contraindicated.
  • The LAA is a thin-walled structure. Use caution when accessing the LAA, and deploying, recapturing, and repositioning the Closure Device.
  • Use caution when introducing a WATCHMAN Access System to prevent damage to cardiac structures.
  • Use caution when introducing the Delivery System to prevent damage to cardiac structures.
  • To prevent damage to the Delivery Catheter or Closure Device, do not allow the WATCHMAN FLX Device to protrude beyond the distal tip of the Delivery Catheter when inserting the Delivery System into the Access Sheath.
  • If using a power injector, the maximum pressure should not exceed 100 psi.

PATIENT SELECTION FOR TREATMENT

In considering the use of the WATCHMAN FLX Device, the rationale for seeking an alternative to long-term anticoagulation therapy and the safety and effectiveness of the device compared to anticoagulation should be taken into account.

  • The presence of indication(s) for long-term anticoagulation therapy, other than non-valvular atrial fibrillation (e.g. mechanical heart valve, hypercoagulable states, recurrent deep venous thrombosis).

Details regarding the indications, contraindications, warnings, and precautions for oral anticoagulants approved for patients with non-valvular atrial fibrillation are provided in their respective Instructions for Use. Of note:

  • The safety and effectiveness (and benefit-risk profile) of the WATCHMAN FLX Device has not been established in patients for whom long-term anticoagulation is determined to be contraindicated.

Factors that need to be considered for the WATCHMAN FLX Device and implantation procedure include the following:

  • Overall medical status, including conditions which might preclude the safety of a percutaneous, transcatheter procedure.
  • Suitability for percutaneous, transseptal procedures, including considerations of:
    • Cardiac anatomy relating to the LAA size and shape.
    • Vascular access anatomy (e.g., femoral vein size, thrombus, or tortuosity).
    • Ability of the patient to tolerate general or local anesthesia.
    • Ability of the patient to undergo required imaging.
    • Ability to comply with the recommended post-WATCHMAN FLX Device implant pharmacologic regimen (see Post-Procedure Information section) especially for patients at high risk for bleeding.

ADVERSE EVENTS

Potential adverse events (in alphabetical order) which may be associated with the use of a left atrial appendage closure device or implantation procedure include but are not limited to:

  • Air embolism
  • Airway trauma
  • Allergic reaction to the contrast media, anesthetic, WATCHMAN Implant material, or medications
  • Altered mental status
  • Anemia requiring transfusion
  • Anesthesia risks
  • Angina
  • Anoxic encephalopathy
  • Arrhythmias
  • Atrial septal defect
  • Bruising, hematoma, or seroma near the catheter insertion site
  • Cardiac perforation
  • Chest pain discomfort
  • Confusion post procedure
  • Congestive heart failure
  • Contrast related nephropathy
  • Cranial bleed
  • Death
  • Decreased hemoglobin
  • Deep vein thrombosis
  • Device embolism
  • Device fracture
  • Device thrombosis
  • Edema
  • Embolism
  • Excessive bleeding
  • Fever
  • Fistula
  • Groin pain
  • Groin puncture bleed
  • Hematuria puncture
  • Hemoptysis
  • Hypotension
  • Hypoxia
  • Improper wound healing
  • Inability to reposition, recapture, or retrieve the device
  • Infection/pneumonia
  • Interatrial septum thrombus
  • Intratracheal bleeding
  • Major bleeding requiring transfusion
  • Misplacement of the device/improper seal of the appendage/movement of device from appendage wall
  • Myocardial erosion
  • Nausea
  • Oral bleeding
  • Pericardial effusion/tamponade
  • Pleural effusion
  • Prolonged bleeding from a laceration
  • Pseudoaneurysm
  • Pulmonary edema
  • Renal failure
  • Respiratory insufficiency/failure
  • Stroke - Hemorrhagic
  • Stroke - Ischemic
  • Surgical removal of the device
  • TEE complications (e.g., throat pain, bleeding, esophageal trauma)
  • Thrombocytopenia
  • Thrombosis
  • Transient ischemic attack (TIA)
  • Valvular or vascular damage
  • Vasovagal reactions

There may be other potential adverse events that are unforeseen at this time.

92574167 A.1